Pure Sine Wave, 5000 W:
Product Features:
High conversion efficiency and fast startup;
Pure sine wave output;
Soft-start function;
Strong load adaptability and stability;
Provides overcurrent and short-circuit protection to prevent electrical equipment damage;
The fan is controlled by both temperature and power, ensuring safe and efficient operation; Built-in fuse – safe and reliable.
DC voltage is customizable: 12V,24V,36V,72V,96V, 110V, etc.; AC voltage is customizable: 120V,200V, etc.; sockets for various countries can be customized. Performance Specifications
The L5000I sits at the top of our outdoor mobile power range. It holds 5000 W continuously and carries 10,000 W for 5 ms — a window that decides whether a fridge compressor, an air-conditioner or a well pump starts cleanly or trips the unit into protection. Input is 12 V, 24 V or 48 V from a lithium bank; output is 110 VAC ±10% or 220 VAC ±5% at 50 Hz or 60 Hz ±1%, with total harmonic distortion under 3%. In practice this is a dc to ac power inverter sized for the loads that sent you looking for a large one in the first place.
We build it in Nanjing as a power inverter manufacturer with our own full-power development platform and pilot base, not as a trading house relabelling someone else's carton. Protection thresholds, fan logic and the cooling path on this model were set for continuous duty in vehicles and site cabins — expedition campers and welfare vans, work trucks, off-grid cabins, telecom shelters, electric utility carts and industrial vehicles running large house banks.
| Parameter | Rating |
|---|---|
| Output power | 5000 W |
| Peak power | 10,000 W (within 5 ms) |
| Input voltage | 12 V / 24 V / 48 V nominal |
| Output voltage | 110 VAC ±10% / 220 VAC ±5% |
| Output frequency | 50 Hz ±1% / 60 Hz ±1% |
| Discharge waveform | Pure sine wave |
| Waveform distortion | THD 86% (DC 13 V) / >88% (DC 26 V) / >90% (DC 52 V) |
| Overload protection | 112%–114% |
| Operating ambient temperature | –10 °C to +50 °C (customizable: –40 °C cold startup) |
| Storage ambient temperature | –30 °C to +70 °C |
| Humidity | 20%–90% RH (no condensation) |
| Operating altitude | ≤ 1200 m |
| Product size | 545 × 199 × 146 mm |
Two figures decide whether an installation works: 5000 W continuous and 10,000 W for 5 ms. The continuous figure is what the unit will hold indefinitely without derating. The peak figure is inrush headroom — the instant a motor or compressor pulls several times its running current before the rotor turns. A dc to ac power inverter without that headroom either trips on start-up or refuses to start the load at all, which is why the peak window is quoted in milliseconds rather than seconds.
Add up what will actually run at the same moment, in watts, at the worst point in the day. A 5000 W budget covers, for example, a medium air-conditioner with lights and electronics running alongside it, but a kettle, a microwave or an induction hob each take a large share on their own. Motors are the trap: a pump or compressor rated at 1 kW of output can pull close to three times that for a fraction of a second, and two of them starting together can use the whole peak window even when their running load looks comfortable.
The battery side is where a unit of this size is really decided. At full output the DC current is roughly 100 A on a 48 V bank, 200 A on 24 V and 400 A on 12 V before losses, so the pack, the BMS and the cable all have to deliver that continuously, not just at the moment you measure it. A large-format lithium pack with a BMS rated above the continuous current, short heavy cable and a fuse at the battery end is the standard arrangement.
Nothing on the DC side behaves like a dc power supply. There is no regulated output to dial in and no assumption that the input sits at one fixed voltage: the converter follows the bank across 10.6–15.5 V, 21.2–31 V or 42–61.8 V and holds 110 V or 220 V AC on the other side, which is exactly what a bank sagging under a heavy load needs.
| Configuration | DC input window | AC output | Net weight |
| 12 V / 110 V | 10.6–15.5 V | 110 VAC ±10% | 12.46 kg ±0.03 kg |
| 24 V / 110 V | 21.2–31 V | 110 VAC ±10% | 12.45 kg ±0.02 kg |
| 48 V / 110 V | 42–61.8 V | 110 VAC ±10% | 12.26 kg ±0.02 kg |
| 12 V / 220 V | 10.6–15.5 V | 220 VAC ±5% | 12.46 kg ±0.03 kg |
| 24 V / 220 V | 21.2–31 V | 220 VAC ±5% | 12.1 kg ±0.02 kg |
| 48 V / 220 V | 42–61.8 V | 220 VAC ±5% | 12 kg ±0.02 kg |
Two protection layers, one order of operation. A lithium pack with its own BMS and this inverter both watch the same DC voltage, and the most common integration mistake is letting them act at the same moment or in the wrong order. The inverter gives its own warning first: the red LED and buzzer at 10.5 ±0.3 V on a 12 V build, 21 ±0.6 V on 24 V and 42 ±1 V on 48 V, then an undervoltage shutdown at 9.5 ±0.2 V, 19 ±0.3 V or 38 ±0.5 V, with automatic restart once the bank climbs back to 12.1 ±0.3 V, 24.4 ±0.4 V or 47.7 ±0.4 V. Set the BMS discharge cut-off slightly below the inverter's shutdown point so the inverter is the layer that acts first and the BMS stays in reserve. Reverse the order — BMS set above the inverter threshold — and the AC output disappears with no warning at all, which is exactly the behaviour that gets reported as a fault.
Current is the other half of the agreement. At 5000 W the DC draw is roughly 400 A on a 12 V bank, 200 A on 24 V and 100 A on 48 V before losses, so the pack, the cabling and the BMS continuous discharge rating all have to carry that figure, not the number printed on the inverter case. Ask as well about the BMS overcurrent trip. The 10,000 W peak lasts only 5 ms and sits well inside most delayed trip windows, but an instantaneous threshold set close to the continuous rating can still open the contactor on a hard motor start.
A hard disconnect is not a normal shutdown. When a BMS opens its contactor under a 5 kW load, the input falls to zero in one step instead of through the inverter's controlled sequence. Do that repeatedly and the front end takes stress it was never asked to absorb. Shed the largest loads as the bank approaches its floor, and treat the BMS as the last line of defence rather than the working cut-off.
No data link, so plan for a manual reset. This dc power inverter has no CAN connection to the pack; coordination happens entirely through the two sets of voltage settings. Some lithium BMS units latch off after a protection event and wait for a charger or a button before they reconnect, while others close again on their own. The inverter recovers automatically from undervoltage, but if the BMS is latched the AC output stays off until somebody resets the pack — worth confirming before an unattended cabin or site shelter relies on it.
Temperature narrows the window. The L5000I is rated for –10 °C to +50 °C operation, with –40 °C cold startup as a build option, but the BMS temperature window is usually the tighter of the two. If the pack limits discharge current when cold, a full 5 kW load can exceed that limit while the bank voltage still looks healthy on a meter.
Send us the bank chemistry, nominal voltage, BMS continuous and peak discharge ratings, cut-off and recovery set points, and the largest single load you plan to start. We will check the model configuration and the cut-off values against them before the order is released.
Buying power-conversion hardware rarely fails on the unit itself; it fails on the match. Tell our engineers the input and output voltages, the current your load draws and how the unit will be controlled and mounted, and they will confirm the right configuration or quote a customized one. Lincoren has run its own full-power R&D platform and pilot base in Nanjing since 2010, so selection, wiring and commissioning questions go to the people who designed the unit, not to a call centre. Fault diagnosis and replacement support continue after delivery.
Yes. The unit draws through the BMS like any other load, and the input window is fixed by the model you order. The one setting worth coordinating is the low-voltage cut-off: set the pack's cut-off slightly below the inverter's own alarm point so the red LED and buzzer warn you first. If the BMS drops the pack before the inverter alarms, every shutdown looks like a fault and you lose the chance to shed a load. This dc to ac power inverter has no data link to the pack, so coordination happens through those two voltage settings.
It only inverts. Power flows one way here: DC in from the bank, AC out to the loads. Charging is a separate device — normally an on-board charger or an ac to dc power supply matched to the pack — and in a vehicle installation the two sit on opposite sides of the battery, one feeding it and one drawing from it, so they run at the same time without conflict.
Either, at ±1%. The frequency is set for the order, so tell us which grid you are matching. It matters for anything with a synchronous motor, a mains-referenced clock or a transformer wound for one frequency: a 60 Hz appliance run at 50 Hz turns slower and can overheat, and the reverse runs it fast. Resistive loads such as kettles, heaters and incandescent lamps do not care.
Less than the equipment around it. Keep the fan grille and heatsink fins clear of dust, straw and workshop debris, check the DC terminal torque once a year, and inspect the cable where it passes through a bulkhead. In agricultural or construction use, blow the unit out with dry compressed air every few months — a blocked fan is the usual cause of a nuisance overtemperature shutdown.
The standard build is rated for operation from –10 °C to +50 °C. Fleets that work through real winters — cold-store operations, northern site vehicles, high-altitude installations — should specify the –40 °C cold startup option when the unit is ordered, since it is a build option rather than something fitted later.