Product Overview
The LK1660 is a 3.3 kW on-board charger that works in both directions. Connected to a single-phase supply it charges the traction pack; parked, the same power stage sends energy back out to run AC loads — vehicle-to-load for tools and appliances, or vehicle-to-home when a building circuit needs support during an outage.
Everything sits in one air-cooled assembly, sealed to IP67 for underbody and wet-bay mounting. There is no coolant to fill, no hose to route and no second enclosure to find space for on the chassis.
Control is fully digital, with active power factor correction on the input and CAN communication to the vehicle controller and the battery management system.
Six output variants share one platform. They differ in the voltage window they present to the pack, so a low-voltage golf cart and a high-voltage traction pack use the same control board, the same firmware toolchain and the same sealing.
This dc charger suits builders who need the pack to do more than accept charge: specialty EV and low-speed vehicle makers, RV and van converters wiring AC appliances to a house battery, and industrial vehicle manufacturers who want the battery to double as a worksite supply. Lincoren builds these assemblies and supplies them directly to the teams who integrate them.
Bidirectional V2L and V2H Output
- One stage, two directions. In charge mode the assembly works as an ac to dc power supply feeding the pack; in discharge mode the same hardware runs in reverse, taking DC from the pack and producing AC at the output.
- V2L covers the everyday loads. Job-site tools, lighting, a laptop charger, a small compressor, a kettle at a campsite — the equipment that would otherwise need a generator on site.
- V2H covers the building. During a supply outage the vehicle can carry a backed-up circuit, provided the transfer arrangement is designed properly and the amount of charge you are willing to give up is agreed in advance.
- The vehicle has to grant permission. The BMS must allow discharge and the contactors must close in the right order; plan that enable logic with our engineers before the wiring drawing is released.
- Motor loads need headroom. Fridges, compressors and power tools draw several times their running current at start-up, so size the load list against the continuous rating of the discharge path rather than its peak.
- Same capability, two scales. V2L and V2H both draw on the pack through the same bidirectional stage; what differs is what sits downstream — a single socket, or a building transfer switch.
Model Codes and Output Variants
| Model code |
Rated input |
Input range |
Rated output power |
Rated output voltage |
Output voltage range |
Output current range |
| LK1661-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
540 VDC |
0–720 VDC |
0–6 A |
| LK1662-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
360 VDC |
0–500 VDC |
0–10 A |
| LK1663-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
144 VDC |
0–200 VDC |
0–22 A |
| LK1664-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
108 VDC |
0–140 VDC |
0–30 A |
| LK1665-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
72 VDC |
0–95 VDC |
0–45 A |
| LK1666-M04-XX |
220 VAC |
90–265 VAC |
3.3 kW |
48 VDC |
0–68 VDC |
0–60 A |
Digital Control and Communication
Control is digital end to end. Charging voltage and current are set in firmware rather than by analogue trim, which is why one control board serves six very different output windows and why a new pack profile can be handled without a hardware redesign.
Protection is layered. Software supervision and independent hardware limits sit behind the same fault logic, so a stalled sensor or a saturated control loop does not leave the pack unprotected. Trip points and recovery behaviour are set per configuration, and the protection table for the code you are buying is available with the order documentation.
Communication runs over CAN, with bootloader support and background software that allows the built-in parameters to be upgraded in the field. A charge profile, a current limit or a threshold can be changed through the service tool instead of returning the unit for rework.
In practice, each order behaves as a custom dc power supply built around your platform: your maximum charge voltage, your current limit, your signal set. Send the CAN matrix and the charge profile you need at the specification stage — protocol work costs far less before the wiring drawing is frozen.
Cooling, Sealing and Protection
- Air-cooled, no coolant circuit. Heat leaves through the heatsink and moving air, so there is no pump, radiator or hose to route and no coolant to fill, bleed or leak-check at end of line. On a refit where the cooling loop is already fully allocated, that is often the deciding detail.
- Over-temperature protection. The unit watches its own thermal state and intervenes before the power devices are stressed. The case it exists for is a blocked air path or a hot bay in summer, so treat airflow as a design requirement rather than a preference.
- IP67 sealing. Dust-tight and protected against temporary immersion at that rating, which covers underbody spray, washdown and damp lockers. The enclosure is only as sealed as the glands and connectors you fit to it, so specify those to the same standard.
- Mount it like a heatsink. Give the finned face clear air, avoid a pocket where hot air recirculates, and keep the unit out of direct wheel spray and mud packing.
- Leave room for the service tool. A buried installation turns a parameter update into a bodywork job; plan access at the same time as the mounting points.
Vehicle Applications
Lawn and garden equipment. Ride-on mowers and professional turf machines charge between shifts from whatever single-phase socket is in the yard, and they work in dust and grass clippings. The charging window is short, so the unit has to take a full charge without a long cool-down.
Small electric vessels. Dockside charging runs from a shared shore supply that is rarely clean, and the unit lives in a damp locker. What matters here is tolerance to a poor supply and a housing that does not mind humidity.
Forklifts and high-lift vehicles. Opportunity charging during breaks means several short cycles a day rather than one long one. CAN control lets the charger follow the truck's own charge policy instead of a fixed profile.
Electric motorcycles and scooters. Space, not power, is the constraint — the unit has to fit an envelope designed around a battery, a controller and a motor.
Four-wheel vehicles, tricycles and canopy vehicles. One pack design is often shared across several body styles, so a single output window has to cover a family of vehicles; that is where the current headroom of the lower-voltage codes helps.
Golf carts and low-speed vehicles. Low pack voltage with high current demand is the normal case, and the lower-voltage codes are built for exactly that trade.
Why builders come to us. Teams comparing DC EV charger manufacturers usually start with the charge side, then find that V2L means a second unit, a second mounting position and a second supplier to qualify. Here it is one assembly and one engineering contact for both directions.
In-vehicle Integration Steps
- Fix the pack window first. Nominal voltage, maximum charge voltage and the current you want at the top of the charge define the output code — and that specification is what turns the order into a custom dc power supply matched to your platform rather than a catalogue pick.
- Exchange the CAN matrix. Agree which signals the vehicle sends (enable, voltage request, current request), what the charger returns, how a fault is reported, and where the service tool connects.
- Reserve a mounting position with an air path. Treat the unit like a heatsink: finned face clear, no recirculating pocket, away from wheel spray and heat sources.
- Route and fuse the AC input, the DC output and the CAN wiring to your own vehicle standard. Keep the DC run short and keep signal wiring away from the switching nodes.
- Power up without a charge command. Confirm the unit wakes, reports on CAN and accepts its parameter file before you ask it to deliver current.
- Commission at partial load, then at full load. Watch the thermal trend across a complete charge, log the parameters you settled on and record the firmware version in the service file.
Ordering and Delivery
- Configuration on paper first. Every order is built to a model code plus a parameter file. Approve both in writing; a change after the drawing is released moves the schedule.
- Supply conditions. Confirm the single-phase supply your customers will charge from — nominal voltage and tolerance. It decides how the ac to dc power supply is set and which input figure applies to your order.
- Quantity and schedule. Tell us the build quantity and the date you need units on the line; we confirm the schedule against the configuration and the current production plan.
- Drawings and documentation. Ask for the interface drawing, the CAN signal list and the protection table for the code you are buying, so your integration file is complete before the first build.
- Samples and validation units. If you need a unit to validate before committing to a production order, ask your sales contact about sample availability and the configuration it can be supplied in.
- Packing and transport. Export packing and freight terms are agreed per order and destination; confirm them with your sales contact when the order is placed.
- Warranty and after-sales. Warranty terms, spares and returns handling are set out in the quotation for your order rather than fixed here.
- Requirements outside the standard range. A different connector set, parameter file or output window is engineering work; send it early so feasibility and schedule can be confirmed.
AC Input and Auxiliary Supply
- One input stage, two quoted windows. The unit takes single-phase mains through an active power factor correction front end. The platform is accepting a full-range 90~290 VAC input, while every model code in the variant table is qualified at 90–265 VAC. The table figure is the one attached to the code you order; treat the wider figure as platform headroom rather than a per-unit rating, and ask us to confirm both in writing for the grid your customers actually charge from.
- What happens at the edges of the window. At the bottom of the range the unit pulls more input current to hold the same output power, so size the breaker, the shore socket and the input cabling against the lowest supply voltage you expect on site, not against a nominal 220 V. Near the top of the window there is regulation headroom, but a site that sits high on the range should still be checked against the confirmed figure before the drawing is released.
- 3.3 kW on a single phase. Output is fixed at 3.3 kW whichever variant you pick, so the input current is set by the mains voltage and by how hard the pack is charging at that moment. That is the number to give the electrician specifying the charge point, and it is the reason a dedicated circuit rather than a shared outlet is worth planning into the installation.
- The 12 V rail is separate. This assembly converts between the AC supply and the high-voltage pack, and stops at the pack terminals. Lights, controllers, contactor coils, instrumentation and the auxiliary battery are fed from a low-voltage rail that this unit does not produce; without a DC-DC stage somewhere in the wiring, that rail has nothing feeding it.
- Nothing gets duplicated either. Because the charger ends at the pack, an existing HV-to-12 V converter in your BOM stays exactly where it is — this unit neither replaces it nor needs a second charger ahead of it. Draw the bill of materials as one ac to dc power supply for the pack, one HV-to-low-voltage converter for the auxiliary rail, and distribution if the pack needs its own PDU.
- If a single enclosure is the goal. We also build an integrated 6.6 kW assembly that puts the OBC, the DC-DC stage and the PDU into one housing for 240–450 VDC packs, with 13.8 V DC on the auxiliary side. Where your platform sits in that voltage class and wiring weight matters more than the 3.3 kW price point, compare the two architectures before the layout is frozen.
- What to send us. The nominal supply voltage and tolerance your customers charge from, the auxiliary rail voltage and current your vehicle needs, and whether distribution is already handled elsewhere. With those three answers we can confirm what this dc charger supplies on its own and what has to come from a separate converter.
Technical Support & Model Matching
Buying power-conversion hardware rarely fails on the unit itself; it fails on the match. Tell our engineers the input and output voltages, the current your load draws and how the unit will be controlled and mounted, and they will confirm the right configuration or quote a customized one. Lincoren has run its own full-power R&D platform and pilot base in Nanjing since 2010, so selection, wiring and commissioning questions go to the people who designed the unit, not to a call centre. Fault diagnosis and replacement support continue after delivery.
FAQ
Q1. How does this differ from the charge-only 3.3 kW unit?
Very little underneath: the same output windows, the same sealed housing and the same CAN interface. The difference is direction — the charge-only version takes energy in, this one also pushes it back out to an AC port. If you are weighing this against other DC EV charger manufacturers' charge-only units, the reverse path is the whole of the difference; the AC output path and the BMS enable still have to be designed into the vehicle.
Q2. How much power can I draw from this dc charger in discharge mode?
The charging path is rated at 3.3 kW. The discharge rating depends on the configuration and on what the vehicle's BMS will allow, so ask us to confirm it for the code you are ordering before publishing a figure to your own customers. Whatever the rating turns out to be, plan the load list around continuous draw rather than start-up peaks.
Q3. The specification shows two different input ranges — which one applies?
The feature list quotes a full-range input of 90–290 VAC, while the variant table gives 90–265 VAC for each model. The table figure is the one tied to the model code you order; if your customers' grids run close to either edge, tell us the nominal voltage and tolerance you design to and we will confirm the applicable window in writing. Active power factor correction keeps the current drawn by the ac to dc power supply input well behaved across that window.
Q4. Can the same charger be re-specified if our pack voltage changes?
Yes. The platform covers several output windows, so a pack change usually means a different code and a new parameter file rather than a new mechanical design — the mounting, the sealing and the CAN interface stay as they are. Send the new pack's nominal and maximum voltage and we will quote it as a custom dc power supply against that specification, and confirm what changes on your side.
Q5. Does this unit also supply the 12 V system?
No. It converts between the AC supply and the high-voltage pack. Stepping the pack down to 12 V for lights, controllers and auxiliaries is a separate DC-DC function — plan both in the cable routing, each with its own mounting position and fusing.